dc.description.abstract | Objetivo: Evaluar la utilidad diagnóstica y terapéutica, la seguridad, eficacia y complicaciones de la enteroscopía con doble
balón (EDB). Materiales y métodos: estudio descriptivo prospectivo realizado en el Servicio de Gastroenterología del Hospital
Guillermo Almenara Irigoyen LIMA-PERÚ, durante el periodo entre julio 2010 a junio 2015. Se realizaron 129 enteroscopías
en 121 pacientes bajo sedación consciente y con preparación previa. Se utilizó un enteroscopio de doble balón EN-450T5
Fujinon. Los pacientes firmaron un consentimiento informado previo al examen. Resultados: La edad promedio fue 56,6
años. Previamente se realizó estudio del intestino delgado con cápsula endoscópica en 77 pacientes (63,6%). La indicación
más frecuente fue la hemorragia digestiva de origen oscuro (61,2%). La vía de abordaje más utilizada fue la anterógrada (69%).
La distancia máxima alcanzada fue de 570 cm por la vía anterógrada. El tiempo promedio de duración por ambas vías fue de
117,45 minutos. Las ectasias vasculares (56,1%) fueron las causas más frecuentes de hemorragia digestiva de origen oscuro. El
rendimiento diagnóstico fue 83,7%, superior a otras series. El procedimiento terapéutico más utilizado fue la termocoagulación
con argón plasma. Al igual que otras series, los pacientes toleraron la EDB muy bien, sin mayores complicaciones. Conclusiones:
En nuestro grupo estudiado la EDB ha demostrado ser una técnica segura, útil y eficaz para el diagnóstico y tratamiento de las
diferentes enfermedades del intestino delgado, sobre todo en la hemorragia digestiva de origen oscuro. | es_PE |
dc.description.abstract | Objective: Evaluate the diagnostic and therapeutic utility, safeness, efficacy and complications of double-balloon enteroscopy
(DBE). Material and methods: This prospective, descriptive study of DBE took place between July 2010 and June 2015 at the
service of Gastroenterology of Hospital Nacional Guillermo Almenara Irigoyen- Lima Peru. 129 DBE were performed in 121
patients with the Fujinon EN-450T5 double balloon enteroscope, with conscious sedation and with previous bowel preparation.
All of them signed an informed consent. Results: The mean age was 56.6 years. Capsule endoscopy intestinal study was
performed previously in 77 patients (63.6%). The most frequent indication for DBE was bleeding of middle intestine (61.2%).
The approach used was more antegrade (69%). The maximum distance reached was 570 cm in antegrade method. The average
duration for both routes is 117.45 minutes. Vascular ecstasies (56.1%) were the most frequent causes of obscure gastrointestinal
bleeding. The diagnostic yield was 83.7%, higher than other series. The most widely used therapeutic procedure was argon
plasma thermo coagulation. Like other studies, patients had good tolerance to the procedure and no major complications.
Conclusions: In our patients studied the EDB has proven to be a secure, useful and efficient technique for the diagnosis and
treatment of several diseases of the small intestine, especially in obscure gastrointestinal bleeding | |
dc.format | application/pdf | es_PE |
dc.language.iso | spa | es_PE |
dc.publisher | Sociedad de Gastroenterología del Perú | es_PE |
dc.relation.uri | https://revistagastroperu.com/index.php/rgp/article/view/2 | |
dc.rights | info:eu-repo/semantics/openAccess | es_PE |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | es_PE |
dc.source | Seguro Social de Salud (EsSalud) | es_PE |
dc.source | Repositorio Institucional EsSalud | es_PE |
dc.subject | Gastroenterología y Hepatología | es_PE |
dc.subject | Enteroscopía de doble balón | es_PE |
dc.subject | Enfermedades intestinales | |
dc.subject | Hemorragia gastrointestinal | |
dc.subject | Double-balloon enteroscopy | |
dc.subject | Intestinal diseases | |
dc.subject | Gastrointestinal hemorrhage | |
dc.title | Rol de la enteroscopía con doble balón en el manejo de la patología del intestino delgado: experiencia en el Hospital Nacional Guillermo Almenara Irigoyen, Lima, Perú. | es_PE |
dc.title.alternative | Rol of double-balloon enteroscopy in the management of small intestine diseases:
experience in the National Hospital Guillermo Almenara Irigoyen, Lima, Peru | |
dc.type | info:eu-repo/semantics/article | es_PE |
dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.02.19 | es_PE |
dc.publisher.country | PE | es_PE |
dc.identifier.doi | https://doi.org/10.47892/rgp.2016.362.2 | |