Show simple item record

dc.contributor.authorHueda-Zavaleta, Miguel
dc.contributor.authorGomez-de-la-Torre, Juan
dc.contributor.authorBarletta-Carrillo, Claudia
dc.contributor.authorFlores-Flores, Cinthya
dc.contributor.authorPiscoche-Botello, Nilver
dc.contributor.authorMiranda-Visalot, Cecilia
dc.contributor.authorMendoza-Farro, Ada
dc.contributor.authorGomez-Colque, Sujey
dc.contributor.authorTaype-Rondán, Álvaro
dc.contributor.authorCopaja-Corzo, Cesar
dc.date.accessioned2024-10-01T02:00:05Z
dc.date.available2024-10-01T02:00:05Z
dc.date.issued2024-09
dc.identifier.citationClinical Epidemiology and Global Health. 2024(29).es_PE
dc.identifier.urihttps://hdl.handle.net/20.500.12959/5150
dc.description.abstractBackground: Tuberculosis (TB) is one of the leading causes of death worldwide. However, an accurate diagnosis contributes to timely treatment, reducing its adverse consequences. The aim of this research was to determine the diagnostic accuracy of the molecular test Xpert MTB/RIF and Xpert MTB/RIF Ultra (Xpert Ultra) for the diagnosis of pulmonary and extrapulmonary TB compared to Löwenstein-Jensen culture. Methods: We conducted a cross-sectional study of diagnostic accuracy. We included samples from patients who attended a Peruvian laboratory between 2011 and 2022. The index test was the Xpert MTB/RIF and Xpert Ultra and the reference standard was Löwenstein-Jensen solid culture for Mycobacterium tuberculosis. We calculated sensitivity, specificity, and positive and negative likelihood ratios. Results: We evaluated 1023 samples, of which 737 were pulmonary samples, 197 tested positive for the Xpert MTB/RIF and Xpert Ultra tests; and 151 tested positive for culture. The Xpert (MTB/RIF and Ultra) showed a joint sensitivity and specificity of: 97 % (95%CI: 93–99) and 93 % (95%CI: 91–95) in pulmonary samples, 100 % (95%CI: 29.2–100) and 98.3 % (95%CI: 94.1–99.8) in cerebrospinal fluid, 66.7 % (95%CI: 22.3–95.7) and 96.8 % (95%CI: 91–99.3) in pleural fluid, 100 % (95%CI: 15.8–100) and 94.3 % (95%CI: 80.8–99.3) in urine. For the detection of pulmonary TB, the Xpert MTB/RIF had a sensitivity and specificity of 97.1 % (95%CI: 89.9–99.6) and 95.6 % (95%CI: 92.9–97.5) and the Xpert Ultra of 97 % (95%CI: 88.5–99.6) 89.5 % (95%CI: 84.9–93.1) respectively. Conclusion: Our results suggest that the Xpert MTB/RIF and the Xpert Ultra are tests with high diagnostic performance for the detection of pulmonary TB and adequate specificity in pulmonary, cerebrospinal fluid, pleural, and urine samples. However, the results for other samples were imprecise.es_PE
dc.formatapplication/pdfes_PE
dc.language.isoenges_PE
dc.publisherIndian Clinical Epidemiology Networkes_PE
dc.relation.urihttps://www.sciencedirect.com/science/article/pii/S2213398424002264es_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/es_PE
dc.subjectDiagnostic performancees_PE
dc.subjectDiagnosises_PE
dc.subjectMycobacterium tuberculosises_PE
dc.titleDiagnostic accuracy of Xpert MTB/RIF and Xpert ultra tests in pulmonary and extrapulmonary tuberculosis compared to Löwenstein-Jensen culturees_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.07es_PE
dc.identifier.doihttps://doi.org/10.1016/j.cegh.2024.101730


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess

El repositorio recopila la documentación y publicaciones institucionales, producto de la investigación y el desempeño en defensa de la competencia, la propiedad intelectual y protección al consumidor, para su difusión en el entorno social y académico. Se difunde en acceso abierto y está alineado con las Declaraciones de Budapest y de Berlín.

Contactos