Show simple item record

dc.contributor.authorLi Salvatierra, Bruno
dc.contributor.authorCalixto-Aguilar, Lesly
dc.contributor.authorRamos-Castillo, Wilder
dc.contributor.authorChacaltana Mendoz, Alfonso
dc.date.accessioned2024-11-04T19:55:05Z
dc.date.available2024-11-04T19:55:05Z
dc.date.issued2023-12-21
dc.identifier.citationRevista de Gastroenterología del Perú. 2024, 43(4).es_PE
dc.identifier.urihttps://hdl.handle.net/20.500.12959/5214
dc.description.abstractLa evaluación de la enfermedad hepática parenquimal suele comprender exámenes de laboratorio y de imagen; sin embargo, en algunos casos se puede requerir una biopsia hepática. La biopsia del hígado guiada por endosonografía se ha reportado como un procedimiento con un rendimiento diagnóstico entre 90 a 100% con un perfil bajo de eventos adversos; sin embargo, no existen estudios que reporten la experiencia y el tipo de técnica empleada en nuestro país. Objetivo: Determinar la efectividad y la seguridad de la biopsia hepática guiada por endosonografía en enfermedad hepática parenquimal. Materiales y métodos: Estudio prospectivo realizado en un hospital público de nivel de atención III-2 en Lima, Perú, el cual incluyó pacientes mayores de 18 años con sospecha de alguna enfermedad hepática parenquimal que fueron sometidos a una biopsia guiada por endosonografía desde marzo del 2018 a octubre del 2022. Resultados: El rendimiento diagnóstico de las biopsias fue de 77,02%, con una longitud media de la muestra obtenida de 13,98 mm (desviación estándar 7,34) y una mediana de 8 espacios porta completos (0-50). Cabe mencionar que solo un 31.25% de procedimientos se realizaron con aguja fina de biopsia (FNB), encontrándose una diferencia significativa entre el tipo de aguja y el rendimiento diagnóstico (p=0,01). El diagnóstico histopatológico más frecuente el de hepatitis autoinmune. Y existieron un 2,08% de complicaciones post procedimiento. Conclusiones:Las biopsias guiadas por endosonografía para el diagnóstico de enfermedad parenquimal hepática tienen una efectividad cercana al 80% en nuestro medio y con un perfil bajo de eventos adversos; sin embargo, se necesitan estudios prospectivos y con un mayor número de pacientes.es_PE
dc.description.abstractParenchymal liver diseases are commonly evaluated by laboratory and imaging studies. However, in some cases a liver biopsy is required. Endoscopic ultrasonography-guided liver biopsy (EUS-LB) has been reported as a procedure with high diagnostic yield (90-100%) with low adverse event profile, but there are not studies which report about the experience and technique in our country. Objective: Determinate the effectiveness and the safety of endosonography-guided liver biopsy in liver parenchymal disease. Materials and methods: A prospective study was conducted at a III-2 level of care Public Hospital in Lima, Peru. It included patients over 18 years of age with suspicion of parenchymal liver disease who underwent EUS-LB for study hepatic parenchymal disease since March of 2018 to October of 2022. Results:The diagnostic yield of the biopsies was 77.02%, with a mean length of the sample of 13.98mm (standard deviation 7.34) and a median of 8 complete portal spaces (0-50). Only 31.25% of the procedures were performed with a fine needle biopsy (FNB), finding a significant difference between the type of needle and the diagnostic yield (p=0.01). The most common histopathological diagnosis was autoinmune hepatitis. There were 2.08% of post-procedure complications. Conclusions: EUS-LB for the diagnosis of liver parenchymal disease had a diagnostic yield close to 80% in our region with a low profile of adverse events. However, more prospectives studies with a larger number of patients are required.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherSociedad de Gastroenterología del Perúes_PE
dc.relation.urihttps://revistagastroperu.com/index.php/rgp/article/view/1592es_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/es_PE
dc.subjectEndosonografíaes_PE
dc.subjectHígadoes_PE
dc.subjectBiopsia por aspiración con aguja finaes_PE
dc.subjectBiopsia con aguja finaes_PE
dc.subjectEndosonographyes_PE
dc.subjectLiveres_PE
dc.subjectBiopsy, fine-needle aspirationes_PE
dc.subjectBiopsy, fine-needle aspirationes_PE
dc.titleEfectividad y seguridad de la biopsia hepática guiada por endosonografía en enfermedad hepática en un hospital público de nivel IIIes_PE
dc.title.alternativeEffectiveness and safety of endosonography-guided liver biopsy in liver disease at a level III public hospitales_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.19es_PE
dc.identifier.doihttps://doi.org/10.47892/rgp.2023.434.1592


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess

El repositorio recopila la documentación y publicaciones institucionales, producto de la investigación y el desempeño en defensa de la competencia, la propiedad intelectual y protección al consumidor, para su difusión en el entorno social y académico. Se difunde en acceso abierto y está alineado con las Declaraciones de Budapest y de Berlín.

Contactos