Show simple item record

dc.contributor.authorPolo-Capuñay, Ana María
dc.contributor.authorSoto-Cáceres, Víctor
dc.contributor.authorDíaz Vélez, Cristian
dc.date.accessioned2023-06-13T20:33:30Z
dc.date.available2023-06-13T20:33:30Z
dc.date.issued2019-02-20
dc.identifier.citationRevista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo. 2015; 8(3).es_PE
dc.identifier.urihttps://hdl.handle.net/20.500.12959/3909
dc.description.abstractIntroducción: Arias M. y Villegas M., en el 2011, realizaron una revisión sistemática, en centros de salud con alta tasa de infecciones, por lo que implementaron medidas preventivas, para contrarrestarlas, reduciendo las bacteremias asociadas a catéter en un 100%. Resar R y col., en el 2012, realizaron un estudio en la que describieron un cumplimiento del Bundle por parte del personal sanitario de 10 a 20%. Objetivo: Cuantificar el cumplimiento del “Care Bundle” para prevención de infección del torrente sanguíneo asociado a catéter intravascular en el HNAAA. Material y Métodos: Estudio no experimental, Descriptivo-Longitudinal. Se trabajó con el programa Epidat 3.1, con una población de 1726 observaciones-día, una proporción esperada de 20%(4), y un nivel de confianza de 95%, obteniéndose 216 observaciones-día. Para la recolección de datos, se utilizará una lista de indicadores (checking list); cuyos resultados serán analizados utilizando frecuencia absoluta y relativa. Resultados: Se tuvo un total de 29 pacientes. Al tomar en cuenta los criterios de Bundle; el cumplimiento del lavado de manos fue de 0%. El uso adecuado de clorhexidina, fue de 33,3% y la limpieza del puerto de inyección de 76.8%. Un 81,5%, utilizó de manera correcta las barreras máximas. Respecto al adecuado sitio de inserción del catéter y la revisión del mantenimiento necesario de la vía, el cumplimiento fue de 100%. Del total de pacientes estudiados, 17 de ellos sufrieron de IIH. Conclusiones: El cumplimiento de los cinco ítems del care Bundle de prevención de infección del torrente sanguíneo por catéter central, fue de 0%.es_PE
dc.description.abstractIntroduction: Arias M. and Villegas M., in 2011, conducted a systematic review, health centers with high rate of infections , so it implemented preventive measures to counter them , reducing catheter-related bacteremia by 100 %. Resar R et al. , In 2012, conducted a study in which they described a Bundle compliance by health staff 10-20 %. Objetive: Quantifying compliance "Care Bundle" for preventing bloodstream infections associated with intravascular catheter AAANH. Material and Methods: Studio not experimental, Descriptive-Longitudinal, quantitative approach. We worked with the Epidat 3.1 software, with a population of 1726 observations-day, an expected ratio of 20% and a confidence level of 95%, yielding 216-day observations. For data collection, a list of indicators (checking list) will be used; the results will be analyzed using absolute and relative frequencies. Results: A total of 29 patients were reported. By taking into account the criteria Bundle; compliance with handwashing was 0%. Proper use of chlorhexidine, was 33.3% and cleaning the injection port 76.8%. 81.5% used correctly maximum barriers. Regarding the appropriate catheter insertion site and review the necessary track maintenance, compliance was 100%. Of the patients studied, 17 of them suffered from IIH. Conclusions: Compliance with the five items of care Bundle prevention of infection of the bloodstream by central catheter was 0%.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherSeguro Social de Salud (EsSalud)es_PE
dc.relation.urihttp://cmhnaaa.org.pe/ojs/index.php/rcmhnaaa/article/view/175es_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/es_PE
dc.subjectBundlees_PE
dc.subjectBacteremiaes_PE
dc.subjectCatéter vía centrales_PE
dc.subjectCentral line catheteres_PE
dc.titleCumplimiento del “care bundle” para prevención de infección del torrente sanguíneo asociado a catéter intravascular en el HNAAA, enero-febrero, 2015es_PE
dc.title.alternativeCompliance "care bundle" prevention of infection associated bloodstream intravascular catheter in hnaaa, january-february, 2015es_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.05es_PE
dc.identifier.doihttps://doi.org/10.35434/rcmhnaaa.2015.83.175


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess

El repositorio recopila la documentación y publicaciones institucionales, producto de la investigación y el desempeño en defensa de la competencia, la propiedad intelectual y protección al consumidor, para su difusión en el entorno social y académico. Se difunde en acceso abierto y está alineado con las Declaraciones de Budapest y de Berlín.

Contactos