Show simple item record

dc.contributor.authorConde Moncada, Roger
dc.contributor.authorMariano Ferreira, Luis
dc.contributor.authorLa Mura, Ricardo
dc.contributor.authorDávila, Oscar
dc.contributor.authorCubas, W. Samir
dc.date.accessioned2026-03-13T19:56:07Z
dc.date.available2026-03-13T19:56:07Z
dc.date.issued2025-12-11
dc.identifier.citationArchivos Peruanos de Cardiología y Cirugía Cardiovascular. 2025;6(4).es_PE
dc.identifier.urihttps://hdl.handle.net/20.500.12959/5984
dc.description.abstractObjetivo. El tratamiento endovascular de los aneurismas aórticos toracoabdominales y paraviscerales complejos, con el desarrollo de nuevos dispositivos, representa uno de los aspectos más desafiantes de la cirugía endovascular. El objetivo de este estudio fue describir la mortalidad perioperatoria a 30 días, las complicaciones mayores posoperatorias y las reintervenciones de los pacientes tratados por aneurismas aórticos complejos mediante dispositivos de endoprótesis ramificadas off-the-shelf (t-BRANCH) y Physician Modified Endografts (PMEGs). Materiales y métodos. El presente trabajo es un estudio observacional, retrospectivo y unicéntrico sobre una base de datos prospectivamente recolectada de cada paciente tratado por aneurisma aórtico complejo registrado en la historia clínica de nuestro centro aórtico de referencia, entre enero de 2020 y diciembre de 2024. Resultados. Se analizaron 51 pacientes con una media de edad de 69,6 ± 10,3 años, siendo varones el 90,2%. El diámetro medio del aneurisma fue de 66,1 ± 15,2 mm. La mortalidad global fue del 9,8%, siendo la mortalidad intrahospitalria temprana en t-BRANCH del 23,1% en comparación con PMEGs del 5,3% (p=0,0977). Dentro de los predictores de mortalidad intrahospitalaria se encontraron el estado físico según la clasificación del estado físico de la Sociedad Americana de Anestesiólogos (ASA) IV (OR = 11.98; IC95%: 1.46–98.7; p = 0.022) y el antecedente de accidente cerebrovascular (ACV) (OR = 13.07; IC95%: 1.06–161.5; p = 0.043). Conclusiones. La reparación endovascular de aneurismas complejos de aorta mediante endoprótesis con PMEGs y dispositivos t-BRANCH muestra resultados favorables con respecto a la mortalidad y las complicaciones mayores posoperatorias, asociadas a una baja tasa de reintervenciones.es_PE
dc.description.abstractObjective. Endovascular treatment of complex thoracoabdominal and paravisceral aortic aneurysms represents one of the most demanding challenges in endovascular surgery, driven by the development of new devices. This study aimed to describe the 30-day perioperative mortality, major postoperative complications, and reinterventions in patients treated for complex aortic aneurysms using off-the-shelf branched endografts (t-BRANCH) and Physician-Modified Endografts (PMEGs). Materials and Methods.This was a single-center, retrospective, observational study based on a prospectively collected database including all patients treated for complex aortic aneurysms and recorded in their medical records at our reference aortic center between January 2020 and December 2024. Results. A total of 51 patients were analyzed, with a mean age of 69.6 ± 10.3 years; 90.2% were male. The mean aneurysm diameter was 66.1 ± 15.2 mm. Overall mortality was 9.8%, with early in-hospital mortality of 23.1% in the T-Branch group compared to 5.3% in the PMEG group (p = 0.0977). Predictors of in-hospital mortality included an American Society of Anesthesiologists (ASA) physical status classification of IV (OR = 11.98; 95% CI: 1.46–98.7; p = 0.022) and a history of stroke (OR = 13.07; 95% CI: 1.06–161.5; p = 0.043). Conclusions. Endovascular repair of complex aortic aneurysms using PMEGs and t-BRANCH devices shows favorable results with respect to mortality and major postoperative complications associated with a low rate of reinterventions.es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.language.isoenges_PE
dc.publisherSeguro Social de Salud (EsSalud)es_PE
dc.relation.urihttps://apcyccv.org.pe/index.php/apccc/article/view/544es_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/es_PE
dc.subjectAneurisma de la Aorta Toracoabdominales_PE
dc.subjectReparación Endovascular de Aneurismases_PE
dc.subjectMortalidad Hospitalariaes_PE
dc.subjectAortic Aneurysm Thoracoabdominales_PE
dc.subjectndovascular Aneurysm Repaires_PE
dc.subjectHospital Mortalityes_PE
dc.titleReparación endovascular de aneurismas aórticos complejos: comparación entre endoprótesis modificadas por el cirujano y dispositivos ramificados comerciales en un centro de alta complejidades_PE
dc.title.alternativeEndovascular repair of complex aortic aneurysms: comparison between surgeon-modified endografts and commercial branched devices in a high-complexity centeres_PE
dc.typeinfo:eu-repo/semantics/articlees_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.04es_PE
dc.identifier.doihttps://doi.org/10.47487/apcyccv.v6i4.544


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess

El repositorio recopila la documentación y publicaciones institucionales, producto de la investigación y el desempeño en defensa de la competencia, la propiedad intelectual y protección al consumidor, para su difusión en el entorno social y académico. Se difunde en acceso abierto y está alineado con las Declaraciones de Budapest y de Berlín.

Contactos